PHYSICAL DATA
Ambient temperature range: 20¡Æ to 140¡ÆF.* (-7¡Æ to 140¡ÆC)
Rated total pressure: -20" Hg. to 15 psig.¢Ó (-68 kPa to 103 kPa)
Overpressure: Relief plug opens at approximately 25 psig (172 kPa)
Connections: 1/8"' NPT female high and low pressure taps duplicated - one pair
side and one pair back.
Housing: Die cast aluminum. Case and aluminum parts Iridite-dipped to withstand
168 hour salt spray test. Exterior finish is baked dark gray hammerloid.
Accuracy: Plus or minus 2% of full scale (3% on - 0 and 4% on - 00 ranges),
throughout range at 70¡ÆF. (21¡ÆC)
Standard accessories: Two 1/8" NPT plugs for duplicate pressure taps, two 1/8"
pipe thread to rubber tubing adapter and three flush mounting adapters with
screws. (Mounting and snap ring retainer substituted for 3 adapters in MP & HP
gage accesso |