PHYSICAL DATA
Temperature Limits: 32¡ÆF(0¡ÆC) (-30¡ÆF(-34.4¡ÆC) for dry air or gas) to 180¡ÆF
(82.2¡ÆC).
Maximum surge pressure: 10 psig. (.7 bar)
Rated pressure:45" (114 cm) w.c.
Pressure connections: 1/8" NPT
Electrical rating: 15 amps, 120 - 480 volts, 60 Hz. AC. Resistive 1/8 H.P. @ 
125 volts, ¨ù H.P. @ 250 volts, 60Hz A.C. Derate to 10 amps for operation at 
high cycle rates.
Wiring connections: 3 screw type, common, normally open and normally closed.
Set point adjustment: Screw type inside conduit enclosure.
Housing: Aluminum die casting with chemical conversion coating for corrosion 
protection; zinc plated steel stamping.
Diaphragm: Molded Silicone rubber. Aluminum diaphragm plate.
Calibration Spring: Stainless Steel. 
Mounting spud: ¨ö" pipe thread.
Weight: 1 lb. (454